Operation: In the dividing mode, this flow divider will divert input flow from port 3 to ports 2 and 4, with a 50:50 ratio, regardless of operating pressure. When the flow direction is reversed the valve will combine flows from 2 and 4 to port 3. Synchronizing flow is provided in both the dividing and combining modes at bottomed conditions in cylinder applications and at stalled conditions in motor applications. Features: Hardened parts for long life. Quiet, modulated response. Wide operating flow range. Synchronizing in dividing and combining modes. Floating cage - high installation torque. Ports: #6 SAE (9/16-18 ORB Thread). Buna N seals. Made in USA. Specifications: Operating Pressure: 5000 PSI. Burst Pressure: 16,000 PSI. Input Flow: 2.5 - 10 GPM (9.5 - 38 lpm); Ratio: 50:50. Synchronizing Flow: Approximately 10% of maximum inlet flow. Flow Accuracy: 10% of inlet flow. Operating Temperature: -40 to 100°C (-40 to 212°F).